U.S. Nationwide Preconstruction & Estimating Consulting
CSI Divisions 02–33📞 (317) 751-5969info@insiteestimating.net
Private design review • Selected quantities only Publication rights & release approval pending

A clearer view.
From drawing to detail.

Examine the structure of a measured scope through recorded quantity excerpts and carefully prepared drawing previews.

Inspect the selected quantities

Choose a scope.

DOCUMENT STUDY

Coordinated MEP quantities

Plumbing, mechanical and electrical quantities organized by their recorded CSI divisions.

Selected materials. Saved quantities. Original units.

Plan to quantity.

6 previews
Electrical lighting plan — cropped source page 1
Electrical lighting planE-101 · Source page 1 · cropped preview
1 / 6

22 selected items contain the saved reference E-101.

Electrical lighting planSource page 1 · cropped preview
100%Scroll to inspect · Escape to close
Electrical lighting plan — source page 1

Identity-sensitive title blocks are excluded from these private preview derivatives. Original documents remain unchanged.

90Selected line items
12Scope categories
LF / EA / LS / SFOriginal source units

Inside this excerpt

Item counts by source category. These are not project quantity totals.

Every quantity, in context.

Selected excerpt

Base and adjusted quantities retain the source unit and saved precision. Different units are never added together.

90 matching items · 90 selected in this sample

Selected workbook quantities, not complete project totals
Material / measured scopeBase quantityUnitWith allowance
2" Vent PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F22
Saved adjusted quantity
142.219 LF · 'ESTIMATE '!H22
Saved allowance factor
0.1 · 'ESTIMATE '!G22
Original unit
LF · 'ESTIMATE '!I22
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

129.29LF142.219
3" Vent PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F23
Saved adjusted quantity
66.891 LF · 'ESTIMATE '!H23
Saved allowance factor
0.1 · 'ESTIMATE '!G23
Original unit
LF · 'ESTIMATE '!I23
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

60.81LF66.891
4" Vent PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F24
Saved adjusted quantity
24.53 LF · 'ESTIMATE '!H24
Saved allowance factor
0.1 · 'ESTIMATE '!G24
Original unit
LF · 'ESTIMATE '!I24
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

22.3LF24.53
2" Sanitary PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F25
Saved adjusted quantity
59.84 LF · 'ESTIMATE '!H25
Saved allowance factor
0.1 · 'ESTIMATE '!G25
Original unit
LF · 'ESTIMATE '!I25
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

54.4LF59.84
3" Sanitary PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F26
Saved adjusted quantity
22.979 LF · 'ESTIMATE '!H26
Saved allowance factor
0.1 · 'ESTIMATE '!G26
Original unit
LF · 'ESTIMATE '!I26
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

20.89LF22.979
4" Sanitary PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F27
Saved adjusted quantity
91.069 LF · 'ESTIMATE '!H27
Saved allowance factor
0.1 · 'ESTIMATE '!G27
Original unit
LF · 'ESTIMATE '!I27
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

82.79LF91.069
4" VTR PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F28
Saved adjusted quantity
1.1 LF · 'ESTIMATE '!H28
Saved allowance factor
0.1 · 'ESTIMATE '!G28
Original unit
LF · 'ESTIMATE '!I28
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

1LF1.1
1/2" CW PipePiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F29
Saved adjusted quantity
74.096 LF · 'ESTIMATE '!H29
Saved allowance factor
0.1 · 'ESTIMATE '!G29
Original unit
LF · 'ESTIMATE '!I29
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

67.36LF74.096
3/4" CWPiping · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F30
Saved adjusted quantity
91.674 LF · 'ESTIMATE '!H30
Saved allowance factor
0.1 · 'ESTIMATE '!G30
Original unit
LF · 'ESTIMATE '!I30
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

83.34LF91.674
SCO Stack Cleanout Jay R Smith #4510S(Y)Plumbing Fixtures · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F47
Saved adjusted quantity
2 EA · 'ESTIMATE '!H47
Saved allowance factor
0 · 'ESTIMATE '!G47
Original unit
EA · 'ESTIMATE '!I47
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

2EA2
LV1 Lavatory (ADA Accessible) Kohler #K-20000-0 "Caxton" White Viterous ChinaPlumbing Fixtures · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F48
Saved adjusted quantity
1 EA · 'ESTIMATE '!H48
Saved allowance factor
0 · 'ESTIMATE '!G48
Original unit
EA · 'ESTIMATE '!I48
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

1EA1
WC-1 Water Closet (ADA Accessible) Kohler #K-3519-0 Highline Classic Floor Mounted.Plumbing Fixtures · CSI 22
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F49
Saved adjusted quantity
1 EA · 'ESTIMATE '!H49
Saved allowance factor
0 · 'ESTIMATE '!G49
Original unit
EA · 'ESTIMATE '!I49
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

1EA1
Piping · CSI 22

2" Vent Pipe

Base quantity
129.29
Unit
LF
With allowance
142.219
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F22
Saved adjusted quantity
142.219 LF · 'ESTIMATE '!H22
Saved allowance factor
0.1 · 'ESTIMATE '!G22
Original unit
LF · 'ESTIMATE '!I22
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

3" Vent Pipe

Base quantity
60.81
Unit
LF
With allowance
66.891
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F23
Saved adjusted quantity
66.891 LF · 'ESTIMATE '!H23
Saved allowance factor
0.1 · 'ESTIMATE '!G23
Original unit
LF · 'ESTIMATE '!I23
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

4" Vent Pipe

Base quantity
22.3
Unit
LF
With allowance
24.53
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F24
Saved adjusted quantity
24.53 LF · 'ESTIMATE '!H24
Saved allowance factor
0.1 · 'ESTIMATE '!G24
Original unit
LF · 'ESTIMATE '!I24
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

2" Sanitary Pipe

Base quantity
54.4
Unit
LF
With allowance
59.84
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F25
Saved adjusted quantity
59.84 LF · 'ESTIMATE '!H25
Saved allowance factor
0.1 · 'ESTIMATE '!G25
Original unit
LF · 'ESTIMATE '!I25
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

3" Sanitary Pipe

Base quantity
20.89
Unit
LF
With allowance
22.979
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F26
Saved adjusted quantity
22.979 LF · 'ESTIMATE '!H26
Saved allowance factor
0.1 · 'ESTIMATE '!G26
Original unit
LF · 'ESTIMATE '!I26
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

4" Sanitary Pipe

Base quantity
82.79
Unit
LF
With allowance
91.069
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F27
Saved adjusted quantity
91.069 LF · 'ESTIMATE '!H27
Saved allowance factor
0.1 · 'ESTIMATE '!G27
Original unit
LF · 'ESTIMATE '!I27
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

4" VTR Pipe

Base quantity
1
Unit
LF
With allowance
1.1
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F28
Saved adjusted quantity
1.1 LF · 'ESTIMATE '!H28
Saved allowance factor
0.1 · 'ESTIMATE '!G28
Original unit
LF · 'ESTIMATE '!I28
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

1/2" CW Pipe

Base quantity
67.36
Unit
LF
With allowance
74.096
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F29
Saved adjusted quantity
74.096 LF · 'ESTIMATE '!H29
Saved allowance factor
0.1 · 'ESTIMATE '!G29
Original unit
LF · 'ESTIMATE '!I29
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Piping · CSI 22

3/4" CW

Base quantity
83.34
Unit
LF
With allowance
91.674
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F30
Saved adjusted quantity
91.674 LF · 'ESTIMATE '!H30
Saved allowance factor
0.1 · 'ESTIMATE '!G30
Original unit
LF · 'ESTIMATE '!I30
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Plumbing Fixtures · CSI 22

SCO Stack Cleanout Jay R Smith #4510S(Y)

Base quantity
2
Unit
EA
With allowance
2
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F47
Saved adjusted quantity
2 EA · 'ESTIMATE '!H47
Saved allowance factor
0 · 'ESTIMATE '!G47
Original unit
EA · 'ESTIMATE '!I47
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Plumbing Fixtures · CSI 22

LV1 Lavatory (ADA Accessible) Kohler #K-20000-0 "Caxton" White Viterous China

Base quantity
1
Unit
EA
With allowance
1
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F48
Saved adjusted quantity
1 EA · 'ESTIMATE '!H48
Saved allowance factor
0 · 'ESTIMATE '!G48
Original unit
EA · 'ESTIMATE '!I48
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

Plumbing Fixtures · CSI 22

WC-1 Water Closet (ADA Accessible) Kohler #K-3519-0 Highline Classic Floor Mounted.

Base quantity
1
Unit
EA
With allowance
1
Source details · P101,201,202
Workbook cell
'ESTIMATE '!F49
Saved adjusted quantity
1 EA · 'ESTIMATE '!H49
Saved allowance factor
0 · 'ESTIMATE '!G49
Original unit
EA · 'ESTIMATE '!I49
CSI division
22 00 00 · Plumbing
Drawing reference
P101,201,202
Detail / note
Plan Notes

Values are the workbook’s saved quantities. No pricing or project total is shown.

How to read this sample

This is a selected excerpt from a verified workbook, not a complete project estimate or a priced bid. The allowance factor and adjusted quantity are saved source values, not browser calculations. Source descriptions, units and drawing references are retained. Worksheet names are quoted, including meaningful spaces. Cropped drawing previews provide document context; only explicit source references support sheet matches. No client relationship or project outcome is claimed.

Make your plans bid-ready.

Discuss your drawing set, required trades and deliverables with the estimating team.

Request a similar estimate